Assertion: The tangent galvanometer can be made more sensitive by increasing the number of turns of its coil.
Reason: Current through galvanometer is proportional to the number of turns of coil.
A. If both assertion and reason are true and reason is the correct explanation of assertion.
B. If both assertion and reason are true but reason is not the correct explanation of assertion.
C. If assertion is true but reason is false.
D. If assertion and reason both are false.

1 Answer

0 votes
by (93.9k points)
selected by
 
Best answer
Correct Answer - B
In tangent galvanometer the current through the coil is given `I=(2r)/(nmu_(0)).B_(H) tan thetaimplies tan theta prop n//r`
i.e., by reducing its radius or by increasing number of turns of coil we can increase the sensitivity of tangent galvanometer.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.