A concrete member under control compressive load is called pedestal when the ratio of effective length and least lateral dimension does not exceeds.
1. 3
2. 6
3. 12
4. 60
5.

1 Answer

0 votes
by (103k points)
selected by
 
Best answer
Correct Answer - Option 1 : 3

Explanation:

  • As per CI.26.5.3.1(h) of IS 456:2000 defines pedestal as a compression member when effective length of the compression member is less than 3 times of The least lateral dimension.
  • As per Cl.25.1.1 of IS 456: 2000 defines a column as a compression member when the effective length of the compression member exceeds three the least lateral dimensions.
  • For pedestals (le/D < 3), a minimum reinforcement of 0.15% of the gross pedestal area is provided.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.