Correct Answer - Option 1 : 1 and 4 only
Efficiency of concrete pump depends on the following factors;
1. Length of horizontal pipe–300 to 400 m
2. Length of vertical pipe
3. Number of bends
4. Diameter of pipe line (150 mm – 200 mm)
5. Slump of concrete (> 75 mm)
6. Capacity of pump
7. Maximum size of Aggregate = 40 mm
8. Performance of Agitation