The efficacy of pumpcrete is based primarily on

1. The capacity of pump

2. The aggregate size, which should not exceed 8 cm

3. The diameter of pipe being large, with more than 30 cm being desirable

4. The performance of the agitator
1. 1 and 4 only 
2. 1 and 2 only 
3. 3 and 4 only 
4. 2 and 3 only

1 Answer

0 votes
by (95.2k points)
selected by
 
Best answer
Correct Answer - Option 1 : 1 and 4 only 

Efficiency of concrete pump depends on the following factors;

1. Length of horizontal pipe–300 to 400 m

2. Length of vertical pipe

3. Number of bends

4. Diameter of pipe line (150 mm – 200 mm)

5. Slump of concrete (> 75 mm)

6. Capacity of pump

7. Maximum size of Aggregate = 40 mm

8. Performance of Agitation

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.