0 votes
1.1k views
in General by (85.8k points)
closed by
A single-phase transformer is rated 110/440 V, 2.5 kVA. Leakage reactance measured from the low-tension side is 0.06 Ω. The per unit leakage reactance will be
1. 0.0062/unit
2. 0.0124/unit
3. 0.0496/unit
4. 0.1983/unit

1 Answer

0 votes
by (96.5k points)
selected by
 
Best answer
Correct Answer - Option 2 : 0.0124/unit

p.u. value = Actual value/ base value

Zbase = V2/S

Voltage rating on low voltage side (V) = 110 V

VA rating (S) = 2.5 kVA

\({Z_{base}} = \frac{{{{110}^2}}}{{2500}}\)

Per unit value \( = \frac{{0.06 \times 2500}}{{{{110}^2}}} = 0.0124\)

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.