In a centrifugal compressor, the highest Mach number leading to shock wave in the fluid flow occurs at
1. Diffuser inlet radius
2. Diffuser outlet radius
3. Impeller inlet radius
4. Impeller outlet radius

1 Answer

0 votes
by (152k points)
selected by
 
Best answer
Correct Answer - Option 3 : Impeller inlet radius

When the Mach number at impeller inlet radius exceeds unity, the air gets deflected through certain angle before its entry into the radial channel of the impeller vane. This leads to formation of shockwave which cause a rapid increase in the lossless.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.