If COP of Carnot refrigeration system is 2 and so to produce refrigerant effect of 5 kW find work input required in kW.
1. 12.5
2. 2.5
3. 10
4. 1.25

1 Answer

0 votes
by (110k points)
selected by
 
Best answer
Correct Answer - Option 2 : 2.5

Concept:

Coefficient of performance of the refrigeration system working on reversed Carnot cycle:

\({\rm{COP}} = \frac{{{\rm{RE}}}}{{{{\rm{W}}_{{\rm{net}}}}}} = \frac{Q}{W} = \frac{{{T_L}}}{{{T_H} - {T_L}}}\)

Unit of refrigerating effect = One tonne of refrigeration

Calculation:

Given:

COP = 2, R.E = 5 kW

\({\rm{COP}} = \frac{{{\rm{RE}}}}{{\rm{W}}} = 2=\frac{5}{W}\)

W = 2.5 kW

COP of a heat pump: 

\(CO{P_{HP}} = \frac{{{T_H}}}{{{T_H} - {T_L}}}\)

Related questions

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.