During tensioning of prestressing tendons the breakage of wires in any one prestressed concrete member shall not exceed
1. 2.5%
2. 7.5%
3. 10%
4. 12.5%

1 Answer

0 votes
by (105k points)
selected by
 
Best answer
Correct Answer - Option 1 : 2.5%

Explanation:

As IS 1343 (1980): Code of practice for Prestressed Concrete 13.2.3

Breakage of Wires:

  • The breakage of wires in any one prestressed concrete member shall not exceed 2.5 percent during tensioning.
  • If the breakages are more than 2.5 percent, they shall be examined and corrective actions are taken.
  • Wire breakages after anchorage, irrespective of percentage, shall not be condoned without special investigations.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.