A tile drainage system draining 12 hectares, flows at a design capacity for two days, following a storm. If the system is designed using a drainage coefficient of 1.25 cm, how much of water will be removed during this period ?
1. 1500 m3
2. 4500 m3
3. 3000 m3
4. 3500 m3

1 Answer

0 votes
by (115k points)
selected by
 
Best answer
Correct Answer - Option 3 : 3000 m3

Concept:

The drainage coefficient is defined as the depth of water to be removed in 24 hours from the entire drainage area.

  • It is used for the design of drainage systems for agricultural lands.
  • In agricultural lands, open ditches or drains are the most commonly used surface drainage structures.
  • The rate at which the open drains should remove water from a drainage area depends on:
    • Rainfall
    • Size of the drainage area
    • Characteristics of the drainage area
    • Nature of the crops grown
    • The degree of protection required for them from waterlogging

​Calculation:

Given:

Drainage coefficient = 1.25 cm/day

Area = 12 ha = 120000 m2

(1 ha = 10000 m2)

Water removal period = 2 days

The volume of water removed = Drainage coefficient × Area × Time = (1.25/100) × 120000 × 2 = 3000 m3

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.