In an alternator at leading power factor, the armature flux _____ the rotor flux.
1. does not affect
2. opposes
3. distorts
4. aids

1 Answer

0 votes
by (114k points)
selected by
 
Best answer
Correct Answer - Option 4 : aids

Concept:

Armature reaction:

The effect of armature (stator) flux on the flux produced by the rotor field poles is called armature reaction. It depends on the power factor i.e. the phase relationship between the terminal voltage and armature current.

  • The armature reaction flux is constant in magnitude and rotates at synchronous speed
  • At unity power factor load, the armature reaction is cross-magnetizing
  • At lagging power factor load, the armature reaction is partly demagnetizing and partly cross-magnetizing; At zero power factor lagging load, it is purely demagnetizing and the induced emf will get decreased
  • When the generator supplies a load at leading power factor the armature reaction is partly magnetizing and partly cross-magnetizing; At zero power factor leading load, it is purely magnetizing and the induced emf will get increased

 

Application:

As the effect of armature reaction is majorly magnetizing, the armature flux aids the rotor flux.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.