The minimum depth of the reinforced bond provided as strengthen arrangement in masonry building is
1. 75 mm
2. 60 mm
3. 50 mm
4. 40 mm

1 Answer

0 votes
by (114k points)
selected by
 
Best answer
Correct Answer - Option 1 : 75 mm

Explanation

Bands are provided in the walls to tie them together and to impart horizontal bending strength in them.

Based on the location, Bands are classified into three categories 

  • Lintel band – provided at lintel levels.
  • Roof band – provided immediately below the roof or floor.
  • Gable band – provided at the top of gable masonry below the purlins.

As per IS4326:1993, cl. 8.4.5, Table 6,

The vertical thickness (i.e. depth) of RC band be kept 75 mm, while width of RC band is assumed same as the thickness of the wall which should not be less than 200 mm.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.