0 votes
184 views
in General by (114k points)
closed by
According to IS 456-2000, nominal cover for reinforcements in case of footings, under 'very severe' exposure:
1. shall not be less than 30 mm
2. shall not be less than 25 mm
3. shall not be less than 50 mm
4. shall not be less than 40 mm

1 Answer

0 votes
by (115k points)
selected by
 
Best answer
Correct Answer - Option 3 : shall not be less than 50 mm

Concept:

As per IS 456 : 2000, Table 5;

Environment

Maximum grade of RCC

Minimum grade of PCC

Nominal Cover

1. Mid

M – 20

-

20 mm

2. Moderate

M – 25

M 15

30 mm

3. Severe

M – 30

M 20

45 mm

4. Very severe

M – 35

M 20

50 mm

5. Extreme

M - 40

M 25

75 mm

 

Cement content should not exceed 450 kg/m3.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.