Correct Answer - Option 2 : 150
\(\sqrt{2}\) A
Concept:
Torque developed in Induction Motor:
- In the Induction motor, the torque is proportional to the product of flux per stator pole and rotor current.
- In addition to current and flux, the power factor also comes into existence.
And we know that, T ∝ ϕ2I2cosϕ2
Or, T = kϕ2I2cosϕ2
Where I2 is rotor current at standstill
Φ2 is the angle between rotor EMF and rotor current
k is a constant
We have, E2 ∝ ϕ2
⇒ T = k1E2I2cosϕ2 …. (1)
Where E2 is rotor EMF at a standstill and k1 is another constant
If R2 is rotor resistance per phase and X2 is rotor reactance per phase at standstill,
Therefore rotor impedance at standstill per phase is given as,
\({Z_2} = \sqrt {R_2^2 + X_2^2} \)
\({I_2} = {\frac{{{E_2}}}{Z_2}} = \frac{{{E_2}}}{{\sqrt {R_2^2 + X_2^2} }}\)
\(cos{\phi _2} = \frac{{{R_2}}}{{{Z_2}}} = \frac{{{R_2}}}{{\sqrt {R_2^2 + X_2^2} }}\)
From equation (1)
\(T = {T_{st}} = {k_1}\frac{{E_2^2{R_2}}}{{R_2^2 + X_2^2}}\)
If the Induction motor is under the running condition and run with slip s,
Er = sE2
And, Xr = sX2
Under this condition torque given as,
\(T = {T_r} = {k_1}\frac{{sE_2^2{R_2}}}{{{{\left( {{R_2}} \right)}^2} + {{\left( {s{X_2}} \right)}^2}}}\)
For developing maximum running torque,
\(\frac{{dT}}{{ds}} = 0\)
s = sm
The torque at any load in an induction motor is the function of slip.
After solving it,
R2 = sm X
And, value of current at maximum starting torque is given as,
\({I_m} = \frac{{{E_r}}}{{\sqrt {R_2^2 + {{\left( {s_m{X_2}} \right)}^2}} }} = \frac{{E_r}}{{\sqrt { {{2R_2}^2}} }} \)
Calculation:
Given,
R2 = 0.1 Ω
X2 = 0.5 Ω
\(s_m = \frac{{{R_2}}}{{{X_2}}} = \frac{{0.1}}{{0.5}} = 0.2\)
E2 = 150 volt
Er = 0.2 × 150 = 30 volt
For maximum torque,
R2 = smX2 = 0.1 Ω
\({I_m} = \frac{{{E_r}}}{{\sqrt {R_2^2 + {{\left( {s_m{X_2}} \right)}^2}} }} = \frac{{E_r}}{{\sqrt { {{2R_2}^2}} }} = \frac{{30}}{{\sqrt { {{2(0.1)}^2}} }} =150\sqrt 2 \;A\)