The internal diameter of the sewer should not be less than
1. 15 cm
2. 25 cm
3. 50 cm
4. 75 cm

1 Answer

0 votes
by (239k points)
selected by
 
Best answer
Correct Answer - Option 1 : 15 cm

As per IS 1742, 1983, the minimum dia of sewer  recommended is 100 mm, since it is not given in option, so  the next higher value of dia recommend ed is 150 mm is the most appropriate.

Other Provisions:

1. The sewer shall be designed for discharging three times the dry-weather flow flowing half-full with a minimum self-cleansing velocity of 0.75 m/s.

2. The minimum gradient for laying sewer is 1 in 57. (For 100 mm dia pipe).

3. Manning’s N to be considered while designing of sewers to be 0.015.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.