The cut-out relay is a safety device for battery. When the generator speed is very low, due to which the output is not sufficient to balance the battery voltage, the necessity to cut out the generator from the battery arises, because otherwise the battery would discharge into the generator. When the engine and hence the generator speed has reached a sufficiently higher value to match its output to the battery voltage the generator should be automatically connected to the battery.