0 votes
244 views
in General by (41.6k points)
closed by
For a two-way simply supported slab of shorter span (upto 3.5 m) with mild steel reinforcement. the span to overall depth is generally taken as: 
1. 35
2. 45
3. 40
4. 20
5. 25

1 Answer

0 votes
by (30.0k points)
selected by
 
Best answer
Correct Answer - Option 1 : 35

Explanation

For two way slab of shorter span (up to 3.5 m) with mild steel reinforcement, the span to overall depth ratios is given below may generally be assumed to satisfy vertical deflection limits for loading class up to 3 kN/m2

Type of Beam

span/depth ratio for 

Mild Steel

span/depth ratio for 

HYSD bars

Simply Supported

35

28

Continuous Slab

40

32

 

Note:

For slabs spanning in two directions, the shorter of the two spans should be used for calculating the span to effective depth ratio.

For high strength deformed bars of grade Fe 415, the value given in the column of mild steel should be multiplied by 0.8 (as mentioned in the third column for HYSD bars).

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.