Concept:
1) Surface Loading Rate (SLR) or Surface Overflow Rate (SOR)
Volume of water applied in unit time per unit surface area of settling tank is known as Surface Loading Rate. It is also denoted by Vo.
\({\rm{SOR\;or\;}}{{\rm{V}}_{\rm{o}}} = \frac{{\frac{{{\rm{Volume\;of\;water\;}}}}{{{\rm{Time}}}}}}{{{\rm{Surface\;area}}}} = \frac{{{\rm{Discharge\;}}}}{{{\rm{Surface\;area}}}}\)
∴ \({\rm{Surface\ area\ of\ filter}} = \frac{{{\rm{Discharge\;}}}}{{{\rm{SOR}}}}\)
It is expressed in m3/d/m2
2) The number of filters required.
\({\rm{n}} = \frac{{{\rm{Total\;surface\;area}}}}{{{\rm{Area\;of\;each\;filter}}}}\)
Calculation:
Area of one filter = 50 m2
Total number of filters working during backwashing = 14 - 2 = 12 filters
Total water filtered in a day= 60 × 60 × 24 = 86400 m3/day
Total surface area of filter working during backwash = 12 × 50 = 600 m2
∴ The required loading rate = \(\frac{{{\rm{86400\;}}}}{{{\rm{600}}}} = 144 \frac{{{m^3}}}{{day\;{m^2}}}\)