A 200 mV full scale dual-slope 3 ½ digit DMM has a reference voltage of 100 mV and a first integration time of 100 ms. For an input of [100 + 10  Cos (100πt)] mV, the conversion time (without taking the auto-zero phase time into consideration) in millisecond is______.

1 Answer

0 votes
by (78.8k points)
selected by
 
Best answer

Given that, Vref = 100 mV

T1 = 100 msec

in = 100 mV

We know that,

Vin T1 = Vref T2

⇒ (100) (100) = (100) (T2)

⇒ T2 = 100 msec

Total conversion time

T = T1 + T2

T = 100 + 100 = 200 ms

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.