As per IS: 800, the splice connection should be designed for a force of at least k times the member design capacity in tension. Here the value of k is:
1. 0.3
2. 0.4
3. 0.5
4. 0.6

1 Answer

0 votes
by (102k points)
selected by
 
Best answer
Correct Answer - Option 1 : 0.3

Explanation

Splices in tension member are provided to joint two sections subjected to tensile force.

Splices connection for tension member is usually bolted connection and it is designed for a force of at least 0.3 times the member design capacity in tension or the design action, whichever is more.

The splice section as well as splice connection are subjected to the tensile loads to be transmitted by the main tension member.

Welcome to Sarthaks eConnect: A unique platform where students can interact with teachers/experts/students to get solutions to their queries. Students (upto class 10+2) preparing for All Government Exams, CBSE Board Exam, ICSE Board Exam, State Board Exam, JEE (Mains+Advance) and NEET can ask questions from any subject and get quick answers by subject teachers/ experts/mentors/students.