Correct Answer - Option 1 : 0.3
Explanation
Splices in tension member are provided to joint two sections subjected to tensile force.
Splices connection for tension member is usually bolted connection and it is designed for a force of at least 0.3 times the member design capacity in tension or the design action, whichever is more.
The splice section as well as splice connection are subjected to the tensile loads to be transmitted by the main tension member.