Correct Answer - Option 3 : 0.15%
Concept:
As per IS 456:2000, Clause 26.5.2.2,
Minimum Reinforcement:
Minimum reinforced (Ast)min in either direction in slabs is given by
\({\left( {{A_{st}}} \right)_{min}} = \left\{ {\begin{array}{*{20}{c}} {0.0015\;{A_g}}&{for\;Fe250}\\ {0.0012{A_g}}&{for\;Fe415} \end{array}} \right.\)
Maximum Diameter:
The diameter of the reinforcing bar shall not exceed one-eighth of the total thickness of the slab.